www.edwardssignaling.com
Integrity Series
INT Monitor Relay
INT-03-024
INT-03-120
INT-03
TUV Notes:
1. Relay conforms to Pollution Degree II, meets EN1760-1:1998, and must be installed
in an IP54-type enclosure.
2. The wire insulation of connected devices must be rated for 250VAC. The relay meets
basic insulation requirements only.
3. Input devices must meet requirements of EN60947-5-1.
4. The relay must be connected to a primary disconnect device that meets the
requirements of EN60947-3.
5. System total response time must not exceed 200ms.
6. Controller meets IP20 and must be connected to safety category 4 mat or
sensing device.
7. Test system before operation and after machine maintenance. Controller does not
require maintenance.
8. The complete system should be tested weekly. If a fault occurs, contact
Sentrol Industrial.
Description
The INT-03-024 or INT-03-120 Safety Monitor Relay is intended for use as a part of a
safety circuit in guard interlock applications. It is a safety relay which uses positive-
guided relays, configured for self-checking, to inhibit machine start-up in the event of
an internal component failure.
Both normally-open and normally-closed inputs are required. Multiple N.O. contacts
can be wired in series while multiple N.C. contacts can be wired in parallel. Upon
failure of either the N.O. or N.C. contact, the relay will turn off and prevent restart.
The INT-03 relay can also monitor contacts on external relays for controlling expansion
block relays (Sentrol INT-05 and INT-06).
INT-03 __________
Installation
Guardswitch
Inputs: Wire the GuardSwitches
in series and in parallel as shown in
the wiring diagram. When first applying power to the GuardSwitch
Monitor Relay,
with no jumper or button from Terminal 1 to Terminal 2, realy will not energize.
With a jumper installed from Terminal 1 to Terminal 2, relay energizes when all guards
are in place (autostart).
With a RESET button installed from Termainal 1 to Terminal 2, relay energizes after
all guards are in place and RESET button is pressed. The monitor contacts must also
be closed.
Authorized Outputs: The designer must perform a risk analysis and be aware of the
applicable safety standards of their machine. The designer has a choice of how to use
the output contacts. The output contacts can be used in combination with an
Emergency Stop Relay circuit with a “reset” function. (“The restoring of an interlocked
safeguard shall not initiate machine motion or operation where this can result in a
hazardous condition. IEC 204-1.) The reset circuit should not be wired to disconnect
power to the GuardSwitch Monitor Relay, or it will be difficult to distinguish between a
GuardSwitch failure and a normal reset function.
Input Power: The GuardSwitch Monitor Relay is available in either a 24 VDC or 120
VAC model. Make sure the correct model is used before applying power as shown in the
wiring diagram.
Dimensions
Slot for 35mm
DIN rail mount
2.46"
6.25cm
1.48"
3.75cm
4.53"
11.5cm
2.95"
7.5cm
2.17"
5.5cm
0.26"
0.66cm
P/N 1030522 • REV D • REB 20MAR13
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Integrity Series

www.edwardssignaling.comIntegrity SeriesINT Monitor RelayINT-03-024INT-03-120INT-03TUV Notes:1. Relay conforms to Pollution Degree II, meets EN1760-1:

Page 2 - Parallel Circuit

RESETASAFE AUX.BCDEFGINT03WIROUTPUTS120 VAC230 VAC60 VDC120 VAC30 VDCLOADSFUSE–+L1 L2 1 2 X1 X2 Y1 Y2N.O. N.C.Safety Monitor RelayINT-03Typical Wiring

Page 3

Category 4 Wiring DiagramGuardSwitches™ are shown with the actuators in position—guard is closed. Inputs are shown with safety/guard in closed positio

Page 4 - AUX Contacts

Ordering/Electrical SpecificationsGeneral SpecificationsUL/CSA/TUV CSA submittedWeight: INT-03-24: 9 oz.INT-03-120/230: 15 oz.Field wiring size 12 gau