Installation Instructions for Rebel Chameleon
TM
125XBRi Series LED Multi-Status Indicator in
NEMA 4X Enclosures
Description
The 125XBRi Series Chameleon Multi-Status LED Indicator
is a UL and cUL listed, multi-color LED signaling appliance
in a NEMA 4X rated enclosure. The indicator can be panel
or conduit mounted. A protective guard, Cat. No. 125GRD,
is also available.
The lights are available in 24V DC and 120V 50/60 Hz. They
are available in either Red/Blue/Amber or Red/Green/Amber.
Edwards Signaling's NEW 125XBRi Multi-status Indicator
is more "chameleon-like" than ever. With our new adaptive
design - one device does it all. With a quick change to the
new 125 Chameleon's dip switch settings, these exible
multi-status indicators instantly adapt for use with or without
control from an external PLC, PAC, or control relay. Now,
regardless of the application you will have just the right device
for the job with only half the inventory.
XTRA-SAFE Enabled
The Chameleon 125XBRi devices ship as standard with
Edwards Signaling's XTRA-SAFE
TM
Technology (patent
pending) Enabled. XTRA-SAFE multi-status indicating
devices employ patented combinations of color AND ash-
rate to provide more denite status indication to those who
are color-blind. With XTRA-SAFE, when Chameleon multi-
status indicators are turned red, they pulse at a rate of 240
ashes per minute, further emphasizing the urgency which
the color red typically connotes. When amber, these devices
pulse at a "less urgent" rate of 120 ashes per minute. When
Chameleon multi-status indicators are turned blue or green
and no other colors are energized, the Chameleon devices
remain "steady-on" and do not ash. Even in extreme cases
where no color is perceived, ash-rate variation provides a
redundant layer of visual indication.
When XTRA-SAFE Technology is enabled, and multiple col-
ors are energized, the device will cycle through the energized
colors at the following pre-set ash-rates:
Red: 240 FPM
Amber: 120 FPM
Green or Blue: 65 FPM
XTRA-SAFE Disabled
While in most cases, the added layer of safety gained by op-
erating a multi-status indicator with XTRA-SAFE Technology
is desirable, some applications may not require differentiation
in ash rates. In other applications, changes do not corre-
spond to escalating levels of urgency. The adaptive design
of the new Chameleon 125 XBRi allows the product to be
adapted to accommodate these requirements by conguring
the dipswitches as shown in Figure 1 (Applications WITH-
OUT a separate PLC or Controller - XTRA-SAFE Technology
Disabled). With XTRA-SAFE Disabled, when red or amber,
P/N 3101611 ISSUE 3
© 2010
http://www.edwardssignaling.com Phone: (800) 336-4206 Fax: (800) 454-2363
the unit pulses at a rate of 65 ashes per minute. When
Chameleon multi-status indicators are turned green or blue
and no other colors are energized, the Chameleon devices
remain "steady on" and do not ash.
When XTRA-SAFE Technology is disabled, and multiple col-
ors are energized, the device will cycle through all energized
colors at 65 FPM.
Externally Controlled
The Chameleon multi-status indicators can also be used in
applications where they will be controlled "externally" using a
Programmable Logic Controller (PLC) or other such external
controller. When externally controlled by a PLC, activation
of colors and ash-rate are fully customizable, and can be
programmatically determined. In applications, where multiple
colors are activated simultaneously, the lights operate on a
priority with red highest, amber second and blue or green,
the lowest. Refer to Figure 1 (Applications WITH a separate
PLC or Controller).
Wire color corresponds with each indicated color.
Red wire = Red LED's
Yellow wire = Amber LED's
Blue with Green tracer wire = Green or Blue LED's
Electrical Specications
GRAY BASE BLACK BASE
Catalog Number Catalog Number Electrical Specs
Red, Green, Amber
125XBRiRGA24D 125XBRiRGA24DB 24V DC, 0.150A
125XBRiRGA120A 125XBRiRGA120AB 120V AC*, 0.100A
Red, Blue, Amber
125XBRiRBA24D 125XBRiRBA24DB 24V DC, 0.150A
125XBRiRBA120A 125XBRiRBA120B 120V AC*, 0.100A
* 120V AC 50/60 Hz
Mechanical Specications
Outdoor Locations
Temperature Ratings ........... -31F to +150F (-35C to +66C)
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - NEMA 4X Enclosures

Installation Instructions for Rebel ChameleonTM 125XBRi Series LED Multi-Status Indicator in NEMA 4X EnclosuresDescriptionThe 125XBRi Series Chameleon

Page 2 - Installation

P/N 3101611 ISSUE 3Installation- Applications with a separate PLC or Controller - Set dipswitches SW1 and SW2 to the OFF position. Table 2. PLC Com

Page 3 - P/N 3101611 ISSUE 3

P/N 3101611 ISSUE 3WARNINGTo avoid risk of injury, install lens before energizing the unit.WARNINGTo prevent electrical shock, disconnect power befo

Page 4 - Maintenance

P/N 3101611 ISSUE 3Wiring (Refer to Figures 3 and 4)AC models1. There are four 18" wire leads: white (neutral), red (for activation o